TROUBLESHOOTING GUIDE
PROBLEM CAUSE REMEDY
Does not run. No input power Turn on the circuit breaker
Indicator lights off. Plug in the line cord
Insure there is power at the outlet
Broken wire • Unplug the machine from power. Examine internally
and rewire at fault.
Bad circuit • Replace if breaker has input power and no output
when in the “ON” position
Bad travel switch Replace if breaker has input power and no output
when “ON”
Does not run. Indicator Wiring short Unplug the machine from power. Examine internally
light off and circuit and rewire at fault.
breaker is tripped.
Burned out part Unplug the machine from power. Examine internally
and replace any part that looks burned up.
Other Can only be determined by factory or qualied repair
person.
Does not run. Indicator Bad connection Unplug the machine from power. Examine internally
light on. and x any broken connections.
Tighten terminal screws on speed control board.
Open transformer Replace the transformer if there is input power on
the primary and no output on the secondary.
(12 VAC/CT is expected.)
Burned out part Unplug the machine from power. Examine internally
and replace any part that looks burned up.
Wiring short Unplug the machine from power. Examine internally
and rewire fault.
Failed motor Replace the motor if it has input voltage and does
not run.
Failed control card Unplug the machine from power. Check the card
for damaged traces or parts. Repair or replace if
required.
Verify the card has 12 VAC/CT input power.
Replace the card if the output to the motor leads is
0 volts with the speed knob at maximum.
Other Can only be determined by factory or qualied
repair person.