PROGRAMMING DATA REQUIREMENTS, CONT’D.
Type 7. Clockwise arc, must be less than 180
0
.
Quadrant determined by direction of end point of arc relative to the start point. (See Chart #2).
Dimensions required:
(1) X-dimension; offset along X-axis from start to end point.
(2) Y-dimension; offset along Y-axis from start to end point.
(3) Radius of arc.
Type 8. Counterclockwise arc, must be less than 180
0
.
Quadrant determined by direction of end point of arc relative to the start point. (See Chart #2).
Dimensions required:
(1) X-dimension; offset along X-axis from start to end point.
(2) Y-dimension; offset along Y-axis from start to end point.
(3) Radius of arc.
R R
L
X
Y
R
X
R
X
X
Y
1
2
3
4
6-2
8
7
Y
Y
CHART #2